Karya Nusatama: Jual Lutron DW-6095 |ISO-9001 3 Phase Power Analyzer

Jual Lutron DW-6095 |ISO-9001 3 Phase Power Analyzer

FEATURES
* Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, Under Indicator * LCD display show " UR ". Frequency
3P/3W, 3P/4W. * The data save into the SD card will show
* 3 current probes ( CP-1201 ) are included, if change the " 9999 " or " 999 " ( overleap the decimal point ). Range Resolution Accuracy
current probes, the calibration procedures are not Real time * Real time data logger, saved the data 45 to 65 Hz 0.1 Hz 0.1 Hz
necessary. data logger into SD memory card and down load
* Current probe input signal/ranges with selection : the all the measured value with the Apparent Power
Input signal (ACV) : time information ( year/month/data/
200 mV/300 mV/500 mV/1 V/2 V/3 V. hour/minute/second ) down load Range Resolution Accuracy
Ranges (ACA) : to the Excel 0.000 to 9.999 KVA *0.001/0.01/0.1KVA ± (1%+0.008KVA)
20 A/200 A/2000 A/30 A/300 A/ 3000 A. * Integration time for data logger : 10.00 to 99.99 KVA *0.01/0.1 KVA ± (1%+0.08KVA)
* Meter can cooperate the universal current probes. 2 seconds to 7200 seconds, the during 100.0 to 999.9 KVA 0.1 KVA ± (1%+0.8KVA)
* Complete set with 4 PCs Test Leads, 4 PCs Alligator clips, of setting step are 2 seconds. 1.000 to 9.999 MVA 0.001 MVA ± (1%+0.008MVA)
3 PCs Clamp Probe ( CP 1201 ), AC to DC 9V adapter, 2 Data Output RS232 computer serial interface : * The resolution is changed according the different ACA range.
G SD memory card and Carrying bag. USB/RS232 * Connect the optional USB cable
* Measurement : * Computer USB-01 will get the USB plug. Reactive Power
V (phase-to-phase), V (phase-to-ground) interface * Connect the optional RS232 cable
A (phase-to-ground) UPCB-02 will get the RS232 Range Resolution Accuracy
KW / KVA / KVAR / PF (phase) plug. 0.000 to 9.999 KVAR *0.001/0.01/0.1KVAR ± (1%+0.008 KVAR)
KW / KVA / KVAR / PF (system) Operating 0 to 50℃ ( 32 to 122℉ ). 10.00 to 99.99 KVAR *0.01/0.1 KVAR ± (1%+0.08 KVAR)
KWH / KVAH / KVARH / PFH (system) Temperature 100.0 to 999.9 KVAR 0.1 KVAR ± (1%+0.8 KVAR)
Phase angle Operating Less than 80% R.H.. 1.000 to 9.999 MVAR 0.001 MVAR ± (1%+0.008 MVAR)
* Harmonics display (1-50th order). Humidity * The resolution is changed according the different ACA range.
* Simultaneous display of Harmonics and Wave form. Power Supply * DC 1.5V, AA ( UM-3 ) Battery X 8 PCs
* Display of Waveform with Peak Values. (Alkaline or heavy-duty battery). Watt Hour ( Active Power Hour) : WH
* Analysis of Total Harmonic Distortion ( THD ). * AC to DC 9V power adapter.
* Graphic Phase diagram with 3-Phase system parameters. Power * Meter : 500 DCmA. Range Resolution Accuracy
* 3 phase Voltage or Current Unbalanced Ratio ( VUR, AUR ) Consumption * Clamp : 34 DCmA. 0.000 to 9.999 KWH 0.001 KWH ± (2%+0.008 KWH)
and Unbalanced Factor. Clamp max. 50 mm ( 2.0 inch ) Dia. 10.00 to 99.99 KWH 0.01 KWH ± (2%+0.08 KWH)
* Calculated Unbalanced Current through Neutral Line ( An ) conductor Size * For the Clamp ,CP-1201 100.0 to 999.9 KWH 0.1 KWH ± (2%+0.8 KWH)
* Capture Transient events (including Dip, Swell and Weight * Meter : 948g ( includes batteries ) 1.000 to 9.999 MWH 0.001 MWH ± (2%+0.008 MWH)
Outage ) with programmable threshold ( % ). * Clamp ( includded cable ) : 467g
* Programmable CT ratio ( 1 to 600 ) and PT ratio ( 1 to Dimension Meter : VA Hour ( Apparent Power Hour ) : SH
1000 ). 225 X 125 X 64 mm
* ACV input impedance is 10 Mega ohms. ( 8.86 X 4.92 X 2.52 inch ) Range Resolution Accuracy
* Safety Standard : IEC 1010, CAT III 600V. Clamp : 0.000 to 9.999 KVAH 0.001 KVAH ± (2%+0.008 KVAH)
* Built-in clock and Calendar, real time data record with SD 210 X 64 X 33mm 10.00 to 99.99 KVAH 0.01 KVAH ± (2%+0.08 KVAH)
memory card , sampling time set from 2 to 7200 ( 8.3 X 2.5 X 1.3 inch ) 100.0 to 999.9 KVAH 0.1 KVAH ± (2%+0.8 KVAH)
seconds. Just slot in the SD card into the computer, it Clamp Jaw : 86 mm (3.4 inch)- outside 1.000 to 9.999 MVAH 0.001 MVAH ± (2%+0.008 MVAH)
can down load the all the measured value with the time Accessories * Instruction manual............... 1 PC
information ( year, month, data, hour, minute, second ) Included * Test Leads (TL88-4AT).......... 1 Set (4 PCs) VAR Hour ( Reactive Power Hour ) : QH
to the Excel directly, then user can make the further data * Alligator clips (TL88-4AC) 1 Set (4 PCs)
analysis by themselves. * Clamp Probe ( CP-1201 )....... 3 PCs Range Resolution Accuracy
* Powered by AA ( UM-3 ) DC 1.5 V X 8 batteries ( Alkaline * AC to DC 9V adapter..............1 PC 0.000 to 9.999 KVARH 0.001 KVARH ± (2%+0.008 KVARH)
type ) or DC 9V adapter. * SD card ( 2 G ).................... 1 PC 10.00 to 99.99 KVARH 0.01 KVARH ± (2%+0.08 KVARH)
* Computer data output, can cooperate with optional USB * Carrying bag......................... 1 PC 100.0 to 999.9 KVARH 0.1 KVARH ± (2%+0.8 KVARH)
Cable/USB-01, RS232 cable/UPCB-02 and Data Optional * 2000 Amp current probe, CP-2000 1.000 to 9.999 MVARH 0.001 MVARH ± (2%+0.008 MVARH)
Acquisition software, SW-811. Accessories * 200 Amp current probe, CP-200
* Optional current probes : CP-1201, CP-2000, CP-200, * Flexible 3000 Amp current probe, Harmonics of AC voltage in Magnitude
CP-3000, detail specification. CP-3000 * Fundamental frequency 50 Hz, 60 Hz
* User can order the meter only ( without the current * USB Cable , USB-01
probes ) with the special request as intend to cooperate * RS232 cable, UPCB-02 Range Resolution Accuracy
their own current probes. * Data Acquisition software, SW-U811 1 to 20th ± ( 2 % + 0.5 V )
* Patented. 21 to 30th 0.1 V ± ( 4 % + 0.5 V )
ELECTRICAL SPECIFICATIONS: 31 to 50th reference
GENERAL SPECIFICATIONS:
Circuit Custom one-chip of microprocessor LSI ACV Harmonics of AC voltage in Percentage
circuit * Fundamental frequency 50 Hz, 60 Hz
Display * LCD Size : Range Resolution Accuracy
81.4 X 61 mm ( 3.2 X 2.4 inch ) 10.0V to 600.0V 0.1V ± (0.5%+0.5V) Range Resolution Accuracy
* Dot Matrix LCD (320 X 240 pixels ) * Phase to neutral line 1 to 20th ± ( 2 % + 10 d )
with back light. 10.0V to 600.0V 21 to 30th 0.1 % ± ( 4 % + 20 d )
Measurement * V (phase-to-phase) * Phase to phase 31 to 50th reference
* V (phase-to-ground)
* A (phase-to-ground) ACA Harmonics of AC current in Magnitude
* KW / KVA / KVAR / PF (phase) * Fundamental frequency 50 Hz, 60 Hz
KW / KVA / KVAR / PF (system) Range Resolution Accuracy
KWH / KVAH / KVARH / PFH (system) 20A 0.001A, < 10 A ± (0.5%+0.1A) Range Resolution Accuracy
* Power factor 0.01A, ≧ 10 A 1 to 20th ± ( 2 % + 0.5 A )
* Phase angle 200A 0.01A, < 100 A ± (0.5%+0.5A) 21 to 30th 0.1 A ± ( 4 % + 0.5 A )
* Frequency 0.1A, ≧ 100 A 31 to 50th reference
* Harmonics display. 1200A 0.1A, < 1000 A ± (0.5%+5A)
Wire 1P/2W, 1P/3W, 3P/3W, 3P/4W. 1A, ≧ 1000 A Harmonics of AC current in Percentage
connections * Fundamental frequency 50 Hz, 60 Hz
Voltage ranges 10 ACV to 600 ACV, auto range. Power factor
Current probe * Current probe input signal volage ( ACV ) : Range Resolution Accuracy
input signal 200mV/300mV/500mV/1V/2V/3V. Range Resolution Accuracy 1 to 20th ± ( 2 % + 10 d )
and range * Current probe input current range ( ACA ) : 0.00 to 1.00 0.01 ± 0.04 21 to 30th 0.1 % ± ( 4 % + 20 d )
20 A/200A/2000A (1200 A)/30A/300A/3000A Remark : 31 to 50th reference
* Meter can cooperate the universal current probe. * PFH : Long term power factor
Safety IEC1010 CAT III 600 V. * PFΣ : Peak value of ACV or ACA
standard For 3Φ 4W, 3Φ 3W
ACV input 10 Mega ohms. PFΣ = ( PF1 + PF2 + PF3 )/3 Range Sample Time Accuracy
impedance 50 Hz 19 us ± ( 5 % + 30 d )
Range select ACV Auto range. For 1Φ 3W 60 Hz 16 us
ACA Manual range. PFΣ = ( PF1 + PF2 )/2 * us = micro seconds
Clamp 40 Hz to 1 KHz.
frequency Φ ( Phase angle ) Crest Factor of ACV or ACA
response
Spec. tested 45 to 65 Hz. Range Resolution Accuracy Range Resolution Accuracy
frequency -180° to 180° 0.1° ± 1° * ACOS ( PF ) 1.000 - 99.99 0.001 ± ( 5 % + 30 d )
Over load ACV 720 ACV rms
protection ACA 1300 ACA with clamp probe Active (Real) Power
* For the Clamp ,CP-1201 Total Harmonic Distortion
Data Hold Freeze the display reading. Range Resolution Accuracy
Data Record SD Card Record. 0.000 to 9.999 KW *0.001/0.01/0.1 KW ± (1%+0.008KW) Range Resolution Accuracy
Sampling Time Approx. 1 second. 10.00 to 99.99 KW *0.01/0.1 KW ± (1%+0.08KW) 0 to 20 % 0.1 % ± ( 2 % + 5 d )
Power ON/OFF Manual OFF by push button. 100.0 to 999.9 KW 0.1 KW ± (1%+0.8KW)
Over Indicator * LCD display show " OL ". 1.000 to 9.999 MW 0.001 MW ± (1%+0.008MW) 20.1 to 100 % ± ( 6 % + 10 d )
* The data save into the SD card will show * The resolution is changed according the different ACA range.
" 9999 " or " 999 "( overleap the decimal point ).

0 komentar:

Posting Komentar

Alamat Kantor

Jl.Jeruk Purut No.52 Rt.003/03,
Kelurahan Cilandak Timur
Kec.Pasar Minggu, Jakarta Selatan.
Kode Pos: 12560.

Hubungi Kami

Senin - Sabtu | 08.00 - 17.00 WIB
Hotline : 081223989651
Marketing 1 WA/Tlp: 085880111657
Marketing 2 WA/Tlp: 085701550255

Email : sales@tokokaryanusatama.com
Email : yogakarya3@gmail.com
Copyright © 2013. Masgus-store Premium Free - All Rights Reserved
Design by Gusti Putu Adnyana Powered by IdBlogsite